Call 08048953297 74% Response Rate

Send Enquiry

our range

Baby Incubator

Offering you a complete choice of products which include nicu incubators unit, open care incubator, premature baby incubator, servo controlled incubator and smart infact incubator.

Nicu Incubators Unit

  • Nicu Incubators Unit
  • Nicu Incubators Unit
  • Nicu Incubators Unit
  • Nicu Incubators Unit
  • Nicu Incubators Unit
  • Nicu Incubators Unit
Nicu Incubators Unit
Get Best Quote
Rs 25,000  / PiecePrice on Request

Minimum Order Quantity: 10 Piece

Product Brochure

Display TypeLCD DISPLAY FOR TREATMENT TIME
Capacity150 liter
MaterialStainless Steel
TypeOpen Care
BrandACCULOC
Usage/ApplicationHospital
Chamber Volume100 Litre
Size100 x 100 x 200 cm
ColorGray
Country of OriginMade in India
OPERATING MODES  SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.  AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.   MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off. Special attention is needed while operating without
ALERTS  Power fail: Power fail indicator turns ON with sound alert (cannot be muted).  Probe fail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp display.  Heater overload: Heater overload indicator turns ON.  Low temperature: Low alarm indicator turns ON with sound alert (can be muted). Displays blinks.  High temperature: High alarm indicator turns ON with sound alert (can be muted). Displays blinks.  Manual mode Time out: Short sound alert and timer flashing on LCD.

Additional Information:

  • Item Code: INC01
  • Production Capacity: 50
  • Delivery Time: 1 DAY
  • Packaging Details: IN BOX

View Complete details

Yes! I am Interested Request a call back

OPEN CARE INCUBATOR

  • OPEN CARE INCUBATOR
  • OPEN CARE INCUBATOR
  • OPEN CARE INCUBATOR
  • OPEN CARE INCUBATOR
  • OPEN CARE INCUBATOR
  • OPEN CARE INCUBATOR
  • OPEN CARE INCUBATOR
  • OPEN CARE INCUBATOR
  • OPEN CARE INCUBATOR
OPEN CARE INCUBATOR
Get Best Quote
Rs 25,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Display TypeLCD DISPLAY FOR TREATMENT & INTENSITY LEVEL
TypeOpen Care
MaterialMILD STEEL
BrandACCULOC
Usage/ApplicationHospital
Country of OriginMade in India
OPERATING MODES  SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.  AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.   MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off. Special attention is needed while operating without
ALERTS  Power fail: Power fail indicator turns ON with sound alert (cannot be muted).  Probe fail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp display.  Heater overload: Heater overload indicator turns ON.  Low temperature: Low alarm indicator turns ON with sound alert (can be muted). Displays blinks.  High temperature: High alarm indicator turns ON with sound alert (can be muted). Displays blinks.  Manual mode Time out: Short sound alert and timer flashing on LCD.

Additional Information:

  • Production Capacity: 50
  • Delivery Time: 1DAY
  • Packaging Details: IN BOX

View Complete details

Yes! I am Interested Request a call back

Premature Baby Incubator

  • Premature Baby Incubator
  • Premature Baby Incubator
  • Premature Baby Incubator
  • Premature Baby Incubator
  • Premature Baby Incubator
  • Premature Baby Incubator
  • Premature Baby Incubator
  • Premature Baby Incubator
Premature Baby Incubator
Get Best Quote
Rs 25,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Display TypeDISPLAY FOR TREATMENT TIME &
TypeOpen Care
MaterialMILD STEEL
BrandACCULOC
Usage/ApplicationHospital
Country of OriginMade in India
OPERATING MODES  SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.  AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.   MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off. Special attention is needed while operating without
ALERTS  Power fail: Power fail indicator turns ON with sound alert (cannot be muted).  Probe fail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp display.  Heater overload: Heater overload indicator turns ON.  Low temperature: Low alarm indicator turns ON with sound alert (can be muted). Displays blinks.  High temperature: High alarm indicator turns ON with sound alert (can be muted). Displays blinks.  Manual mode Time out: Short sound alert and timer flashing on LCD.

Additional Information:

  • Production Capacity: 50
  • Delivery Time: 1 DAY
  • Packaging Details: IN BOX

View Complete details

Yes! I am Interested Request a call back

SERVO CONTROLLED INCUBATOR

  • SERVO CONTROLLED INCUBATOR
  • SERVO CONTROLLED INCUBATOR
  • SERVO CONTROLLED INCUBATOR
  • SERVO CONTROLLED INCUBATOR
  • SERVO CONTROLLED INCUBATOR
  • SERVO CONTROLLED INCUBATOR
  • SERVO CONTROLLED INCUBATOR
  • SERVO CONTROLLED INCUBATOR
SERVO CONTROLLED INCUBATOR
Get Best Quote
Rs 25,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Display TypeLCD DISPLAY FOR TREATMENT, INTENSITY LEVEL
TypeOpen Care
MaterialMILD STEEL
BrandACCULOC
Usage/ApplicationHospital
Country of OriginMade in India
OPERATING MODES  SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.  AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.   MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off. Special attention is needed while operating without
ALERTS  Power fail: Power fail indicator turns ON with sound alert (cannot be muted).  Probe fail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp display.  Heater overload: Heater overload indicator turns ON.  Low temperature: Low alarm indicator turns ON with sound alert (can be muted). Displays blinks.  High temperature: High alarm indicator turns ON with sound alert (can be muted). Displays blinks.  Manual mode Time out: Short sound alert and timer flashing on LCD.

Additional Information:

  • Production Capacity: 50
  • Delivery Time: 1DAY
  • Packaging Details: IN BOX

View Complete details

Yes! I am Interested Request a call back

SMART INFACT INCUBATOR

  • SMART INFACT INCUBATOR
  • SMART INFACT INCUBATOR
  • SMART INFACT INCUBATOR
  • SMART INFACT INCUBATOR
  • SMART INFACT INCUBATOR
  • SMART INFACT INCUBATOR
  • SMART INFACT INCUBATOR
  • SMART INFACT INCUBATOR
SMART INFACT INCUBATOR
Get Best Quote
Rs 25,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Display TypeDISPLAY FOR TREATMENT & INTENSITY LEVEL
TypeOpen Care
MaterialMILD STEEL
BrandACCULOC
Usage/ApplicationHospital
Country of OriginMade in India
OPERATING MODES  SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.  AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.   MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off. Special attention is needed while operating without
ALERTS  Power fail: Power fail indicator turns ON with sound alert (cannot be muted).  Probe fail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp display.  Heater overload: Heater overload indicator turns ON.  Low temperature: Low alarm indicator turns ON with sound alert (can be muted). Displays blinks.  High temperature: High alarm indicator turns ON with sound alert (can be muted). Displays blinks.  Manual mode Time out: Short sound alert and timer flashing on LCD.

Additional Information:

  • Production Capacity: 50
  • Delivery Time: 1DAY
  • Packaging Details: IN BOX

View Complete details

Yes! I am Interested Request a call back

EXPLORE MORE CATEGORIES