Call 08048953297 74% Response Rate

our range

Intensive Care Warmer

Our range of products include radiant warmer pcb controller oem card.
  • Radiant Warmer PCB Controller OEM Card
  • Radiant Warmer PCB Controller OEM Card
  • Radiant Warmer PCB Controller OEM Card
  • Radiant Warmer PCB Controller OEM Card
  • Radiant Warmer PCB Controller OEM Card
Radiant Warmer PCB Controller OEM Card

Radiant Warmer PCB Controller OEM Card

Rs 3,300  / PieceGet Best Price

Product Brochure

TypeDual probe warmer pcb
MaterialDual probe
Model Name/NumberBW5v4
Usage/ApplicationNicu
BrandAPS Embedded Systems
ColorGreen
Height189
Width107
Assay Time MinNA
Length Mm189
Light SourceNA
Number Of WheelsNA
Power V220V AC mains
Temp Range Deg Celsius25 to 38
Thickness MmNA
Wave Length MmNA
Weight Kg1
FeaturesDual Probe
Temperature Measurement Accuracy0.2deg C
Access Door SizeNA
Continuous output speedPID control
Surface FinishNA
Bed TiltingNA
Mobile CastorsNA
Storage TemperatureNA
Operating TemperatureNA
Heating element650W Ceramic Heater
Input Voltage220V AC
Suitable ForRadiant Warmer Nicu
Operating Voltage220V
Load Capacity1000W
Bed CapacityNA
Air Temperature25 to 38
Heater CapacityNA
Control Accuracy0.2 Deg
Footprint SizeNA
Relative HumidityNA
Overall DimensionsNA
Heater RotationNA
Wheel DiameterNA
Heater Wattage650
Temperature Accuracy0.2 Deg
Effective AreaNA
Baby ControlSkin sensor
Product CodeBW5V4
Drawer SizeNA
Country of OriginMade in India

OPERATING MODES
SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 ??C or 101 ??F) in any probe Heater is turned off.
AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 ??C or 101 ??F) in any probe Heater is turned off.
MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 ??C or 101 ??F) in any probe Heater is turned off. Special attention is needed while operating without probes.

Manufactured in Mumbai, Maharashtra, India

 

We deal in Andhra Pradesh, Arunachal Pradesh, Assam,Bihar, Patna, Chhattisgarh, Raipur, Goa, Panaji, Gujarat, surat, ahemdabad, baroda, Gandhinagar, Haryana, Chandigarh, Himachal Pradesh, Shimla, Jharkhand, Ranchi, Karnataka, Bangalore, Kerala,Thiruvananthapuram, Madhya Pradesh, Bhopal, Maharashtra, Mumbai, Manipur, Imphal, Meghalaya, Shillong, Mizoram, Aizawl, Nagaland, Kohima, Odisha, Bhubaneshwar, Punjab, Chandigarh,Rajasthan, Jaipur, Sikkim, Gangtok, Tamil Nadu, Chennai, Telangana, Hyderabad, Tripura, Agartala, Uttarakhand, Dehradun, Uttar Pradesh, Lucknow, West Bengal